<ArticleTitle>Theoretical Study of Indirect Heating Temperature Swing Adsorption ‎in an Adsorbent Coated Finned Tube Heat Exchanger</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>55</FirstPage>
			<LastPage>64</LastPage>
			<ELocationID EIdType="pii">22625</ELocationID>
			
<ELocationID EIdType="doi">10.22108/gpj.2018.106498.1017</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Mohsen</FirstName>
					<LastName>Gholami</LastName>
<Affiliation>Department of Chemical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2017</Year>
					<Month>09</Month>
					<Day>17</Day>
				</PubDate>
			</History>
		<Abstract>In this study, the performance of an adsorbent coated finned tube exchanger for carbon capture was investigated numerically. The results showed that this structure has a great potential for being applied as a medium for CO&lt;sub&gt;2&lt;/sub&gt; capture by rapid indirect thermal swing adsorption. By using this structure, the recovery of 96%, and purity of 98% were achieved with a simple cycle consisting of two steps, including adsorption and regeneration. To assess the effect of operating parameters, the cooling water temperature, hot water temperature and feed flow rate were selected as varying parameters, and the recovery and purity were selected as objective functions.  The results showed that by increasing the cooling water temperature from 25 C to 45 C the recovery decreases from 65% to 61% while the reduction of purity is almost negligible. The heating temperature has a more intense effect on the recovery and purity. By increasing the heating temperature form 80 to 120 the recovery increases from 16% to 65% and purity increases from 92% to 98%. The variation of feed flow rate showed that by increasing the feed from 2 to 6 (STP CM/min) the recovery decreases from 98.5% to 65% and the purity increases from 96% to 98%. It should be noted that finned tube exchangers are well developed to create minor pressure drop. Thus, they are suitable structures for getting coated by adsorbent for the purpose of gas separation by Rapid Thermal Swing Adsorption.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Finned tube</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Coated exchanger</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Rapid thermal swing adsorption</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">CO2 Capture</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://gpj.ui.ac.ir/article_22625_9a2d30f2885802a45938a4ebdd40027c.pdf</ArchiveCopySource>